Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add filters








Year range
1.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 371-376, 2022.
Article in Chinese | WPRIM | ID: wpr-923388

ABSTRACT

@#Objective    To evaluate the short-term therapeutic effect of extended adventitial inversion with graft eversion anastomosis technique in the root treatment of acute type A aortic dissection (ATAAD). Methods    From November 2019 to July 2020, 28 patients with ATAAD were treated by extended adventitial inversion with graft eversion anastomosis technique in the Department of Cardiovascular Surgery, Dalian Municipal Central Hospital, including 19 males and 9 females, aged 60.11±11.11 years. The intima of the ascending aorta was trimed to 5 mm above the sinotubular junction. The adventitia of the ascending aorta was longitudinally cut to the reserved intima margin along the junction of the three aortic valves. The extended adventitial inversion was sutured continuously, no coronary sinus was sutured over the aortic annulus, and the left and right coronary sinus was sutured above the coronary ostium. The anastomotic graft was everted and inserted into the aortic lumen, and the everted graft was continuously sutured at the level of sinotubular junction which was 5 mm away from the edge of graft. Results    There was no intraoperative death, intractable root hemorrhage, residual root false lumen, root dilatation, anastomotic hematoma or other complications. There was no recurrence of the pain in the back of all patients, and the results of the CT angiography were not significantly changed. In 22 patients with no regurgitation, only 1 (4.55%) patient had a mild regurgitation. In 6 patients with mild aortic regurgitation, the disappearance rate of regurgitation was 50.0% (3/6). Conclusion    The treatment of extended adventitial inversion with graft eversion anastomosis technique in the root treatment of aortic dissection eliminates the residual dissection at the root. The anastomotic hemorrhage is prevented, the root structure of aortic dissection is reconstructed and strengthened, the root function is restored, and the possible expansion of the root is prevented. The short-term results are satisfactory.

2.
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12): 188-192, 2021.
Article in Chinese | WPRIM | ID: wpr-885813

ABSTRACT

Due to the emergence of various treatment methods for aortic diseases, the treatment methods of anastomosis have become diversified.The anastomosis of the graft distal eversion partly inserted into the aorta or graft inversion wholely inserted into the aorta increase the joint area between them, and it obviously reduces the impact of tidal blood flow and the lateral force on the anastomosis.Therefore, it has the outstanding advantages of reducing the risk of hemorrhage after anastomosis, simplifying the intraoperative suture operation and easy treatment of anastomotic hemorrhage.Similar techniques with different names are often used in the surgical treatment of aortic lesions and have achieved good anastomosis.In this paper, the concept is uniformly referred to as " Graft Eversion Anastomosis Technique" , and its application evolution in aortic surgery is systematically expounded, so as to further deepen the understanding of the technology.

3.
Chinese Journal of Ultrasonography ; (12): 988-992, 2021.
Article in Chinese | WPRIM | ID: wpr-910149

ABSTRACT

Objective:To compare the diagnostic accuracy of lung ultrasonography and radiography in detection of acute traumatic intrathoracic injuries in children.Methods:A retrospective analysis was performed in 46 cases of children with chest trauma in Shenzhen Children′s Hospital from January 2017 to January 2021. The diagnostic efficiency of lung ultrasound and radiography in children with acute traumatic hemopneumothorax and lung contusion were compared. Computed tomography scan was used as gold standard.Results:The sensitivity and specificity of lung ultrasound were 0.79 and 0.98 for pneumothorax, 0.86 and 0.75 for hemothorax, 0.86 and 0.80 for pulmonary contusion, respectively. Area under the ROC curve of ultrasonography in detection of pneumothorax, hemothorax, and pulmonary contusion was 0.889 (95% CI=0.798-0.979, P<0.001), 0.804 (95% CI=0.707-0.901, P<0.001), and 0.831 (95% CI=0.623-1.000, P=0.013), respectively. Area under the ROC curve of radiography was 0.674 (95% CI=0.544-0.803, P=0.008) for detection of pneumothorax, 0.645 (95% CI=0.517-0.772, P=0.026) for hemothorax, and 0.547 (95% CI=0.289-0.805, P=0.724) for pulmonary contusion. Comparison of area under the ROC curve declared the significant superiority of ultrasonography in detection of pneumothorax, hemothorax and pulmonary contusion (all P<0.05). Conclusions:Lung ultrasound has higher sensitivity and accuracy than chest radiography in the initial evaluation of chest trauma. For children with acute chest trauma, lung ultrasound should be the first choice.

4.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 1423-1428, 2020.
Article in Chinese | WPRIM | ID: wpr-837694

ABSTRACT

@#Objective    To evaluate the value of myocardial perfusion change before and after coronary artery bypass grafting (CABG) in predicting postoperative major adverse cardiovascular events (MACE). Methods    A total of 70 CABG patients who received CABG completed by the same operator from January to November 2017 were selected, including 45 males and 25 females with an average age of 64.83±9.09 years. The patients were divided into two groups according to whether the patients had MACE after 1 year of the surgery, including a non-MACE group (group A, n=60) and a MACE group (group B, n=10). The clinical data of patients were compared. Results    There were statistical difference in the myocardial contrast echocardiography (MCE) score in the group A before and after surgery (P<0.05), and there were statistically significant differences in the left ventricular size and left ventricular ejection fraction (LVEF) value before and 1 year after surgery (P<0.001), but no statistically significant difference in the size of left atrium (P=0.075). There was no significant difference in the preoperative and postoperative MCE score, and preoperative and postoperative 1-year cardiac ultrasound score in the group B (P>0.05). Conclusion    The change of myocardial perfusion after CABG surgery is associated with postoperative MACE. The evaluation of myocardial perfusion before and after CABG surgery is of great significance for the prognosis evaluation of patients.

5.
Chinese Journal of Ultrasonography ; (12): 417-422, 2018.
Article in Chinese | WPRIM | ID: wpr-707691

ABSTRACT

Objective To analysis the change of hip joint in healthy infants by ultrasound,and establish the normal reference value of the developmental dysplasia of the hip(DDH). Methods A total of 8 000 healthy infants from 0 to 24 weeks were collected from the Multi-center study of 10 children′s medical centers. Among them,3 855 infants(2 065 females and 1 790 males) with complete data and follow-up were included in this study. All subjects were divided into 6 groups ( <4,4~7,8~11,12~15,16~19 and≥20 weeks group). α angle,femoral head length and width,femoral head coverage ratio by acetabulum ( FHC) were measured in the coronal view on the neutral position;distance from pubis to femoral head ( P-H) and distance from ischium to femoral head ( I-H ) were measured in the transverse view on neutral position;distance from femoral head topubis ( H-P) was measured in the posterolateraltransverse view on the flexion position. The results of each group changes with age were analysised. Results ① The α angle of healthy infants from 0 to 20 weeks were increased with age,the difference among the groups were statistically significant( P <0.05),but there was no significant difference between 16~19 and ≥20 weeks group( P >0.05). ②The femoral head length and width of all age groups were increased with age,the difference among all the groups was statistically significant( all P <0.05). ③ FHC from 0 to 20 weeks were increased with age,the difference among the groups were statistically significant( P <0.05) except between 16~19 and ≥20 weeks group( P >0.05). ④ The P-H and I-H in all age groups showed no statistically significant ( all P>0.05). ⑤The H-P of all age groups were increased with age,the difference between the groups were statistically significant(all P <0.05).Conclusions The development of hip joints have the certain regular developmental pattern in healthy infants less than 5 months of birth and are relatively constant after birth more than 5 months. The ultrasound normal reference value of the hip joints can be used for the early diagnosis of the DDH.

6.
Chinese Journal of Medical Ultrasound (Electronic Edition) ; (12): 111-118, 2018.
Article in Chinese | WPRIM | ID: wpr-712061

ABSTRACT

Objective To discuss the application of shear wave elastography and strain elasticity imaging diagnosis of infants with congenital muscular torticollis. Methods Children with congenital muscular torticollis in 50 patients and 100 healthy infants were recruited for the research at Shezhen Children′s Hospital in the period of September to December, analyzing factors in normal sternocleidomastoid two mode ultrasonic elastography, including the young′s modulus, shear wave velocity, shear modulus and the ratio of strain results, comparing the change of elasticity between the patients and normal. Results The elastic parameters of the sternocleidomastoid showed no statistically significant difference between the genders, the left side and the right side. The results of young′s modulus, shear wave velocity and shear wave modulus were higher in long axis section than the short axis section, and the difference was statistically significant (P<0.05). However, the results of the strain ratio and thickness was not statistically significant. The young′s modulus, shear wave velocity and shear wave modulus are higher in the stretch back position than symmetrical supine position, and the difference is statistically significant (P<0.05). But those of strain ratio and thickness was not statistically significant. The thickness of the sternocleidomastoid muscle and the young′s modulus, shear wave velocity, shear modulus and the ratio of strain results ultrasound elastic results were higher in the lesion side than the healthy side, and the difference is statistically significant (P<0.05). Conclusion The ultrasound elastic imaging of multimodal technique can quantify the elasticity of the normal infant and the patients sternocleidomastoid, be used for diagnose for the infants with the congenital muscular torticollis.

7.
Chinese Journal of Medical Imaging Technology ; (12): 1057-1060, 2017.
Article in Chinese | WPRIM | ID: wpr-616678

ABSTRACT

Objective To investigate the diagnostic value of ultrasonography in radial head subluxation (RHS).Methods The clinical data and ultrasonographic findings of 34 children with RHS were retrospectively analyzed.All patients were routinely treated by bilateral compared and multi-sectional elbow joints ultrasonography.And the X ray results were negative.Results Ultrasonographic manifestations of RHS included increased radiocapitellar distance in 29 cases (29/34,85.29%);widened joint space and enhanced echo in 25 cases (25/34,73.53%);hook sign,supinator muscle above the radial head in 32 cases (32/34,94.12 %);annular ligament entrapment in 33 cases (33/34,97.06%).Conclusion Ultra sonographic manifestations of RHS have certain characteristics.Comparation of bilateral elbow joints and the application of continuous scanning ultrasound are helpful to make a quick and accurate diagnosis of X-ray negative RHS.

8.
Chinese Journal of Medical Ultrasound (Electronic Edition) ; (12): 165-169, 2015.
Article in Chinese | WPRIM | ID: wpr-637550

ABSTRACT

Objective To investigate the accuracy of three-dimensional ultrasound volumetric measurements for children's bladder. Methods The bladder volumes of 238 children aged 9 months to 16 years (male:106;female:132) in Shenzhen Children's Hospital underwent real-time three-dimensional ultrasound for volume measurements. These cases were divided into six groups according to the body surface area:(0.36~0.60) m2 (27 cases), (0.61~0.78) m2 (66 cases), (0.79~0.89) m2 (52 cases), (0.90~1.05) m2 (33 cases), (1.06~1.20) m2 (30 cases) and (1.21~1.78) m2 (30 cases). The bladder volume measured by GE Voluson E8 and Philips iU22 were compared with the actual volumes of discharge urine. The relation between bladder volume measurements and the actual volume of discharge urine was analyzed. Results Children's bladder volume increasesd with the body surface area (F=33.53, P<0.05) and showed positive correlations with the body surface area (r=0.679, P <0.05). Compared with the actual volume of discharge urine, each group's bladder volume measurements obtained by three-dimensional ultrasound were lower and the results were as follows:[(47.80±30.33) ml vs (82.24±49.63) ml, (77.20±39.72) ml vs (139.98±79.03) ml, (95.96±50.79) ml vs (175.96±101.70) ml, (117.46±54.17) ml vs (206.62±86.22) ml, (145.53±73.60) ml vs (253.33±135.09) ml and (220.27±110.34) ml vs (327.42±165.45) ml]. The differences between children's bladder volume measurements and the actual volume of discharge urine were statistically significant (t=3.19, 5.53, 5.08, 4.49, 3.84 and 3.00, all P <0.05), but children's bladder volume showed positive correlations with the actual urine volume (r=0.881, P<0.05). The bladder volume measurements by spheroid formula based on two-dimensional ultrasound are lower than the actual volume of discharge urine, and the results were as follows:[(50.38±36.94) ml vs (82.24±49.63) ml, (86.77±62.34) ml vs (139.98±79.03) ml, (102.69±60.21) ml vs (175.96±101.70) ml, (107.94±55.14) ml vs (206.62±86.22) ml, (145.31±66.01) ml vs (253.33±135.09) ml and (222.77±132.59) ml vs (327.42±165.45) ml]. The differences were statistically significant (t=3.03, 4.01, 4.47, 4.95, 3.94 and 2.75, all P <0.05), but children's bladder volume showed positive correlations with actual urine volume (r=0.326, P <0.05). Conclusions Three-dimensional ultrasound volumetric measurements for children's bladder is feasible and in clinical application, the factors of children's growth should be take into account. Combing regression equation, children's bladder volume can be more accurately quantified.

9.
Chinese Journal of Medical Ultrasound (Electronic Edition) ; (12): 142-154, 2014.
Article in Chinese | WPRIM | ID: wpr-636333

ABSTRACT

Objective To investigate the reference values and Z scores regression equations of newborn undergoing echocardiography. Methods Two hundred and eighty-eight newborns (aged 0-28 days) of Shenzhen Children′s Hospital underwent echocardiography examination, including M-mode, two-dimensional (2D) and real-time three-dimensional (3D) echocardiography, color Doppler lfow imaging (CDFI) and tissue Doppler imaging. The correlation between echocardiography results and weight were analyzed and Z scores were calculated. Results The normal values of right ventricular diameter (RV) and left ventricular end-diastolic diameter (LVEDD) measured by M-mode, the mitral annulus diameter in four chamber view (MV-D1), mitral annulus diameter in two chamber view (MV-D2), mitral annulus diameter in longitudinal view (MV-D3), aortic ring diameter (ARD), aortic sinus diameter (ASD), ascending aorta diameter (AAO), transverse aorta diameter (TA), aortic isthmus diameter (AI), aorta diaphragm diameter (AO-Dia), tricuspid annulus diameter in four chamber view (TV-D1), tricuspid annulus diameter in right ventricular inlfow tract view (TV-D2), right ventricular outlfow tract diameter (RVOT), pulmonary valve diameter (PVD) and main pulmonary artery diameter (PA) measured by 2D echocardiography and the normal values of mitral valve inflow Doppler component during early diastole (MV-E), mitral valve inlfow Doppler component during atrial contraction (MV-A), tricuspid valve inlfow Doppler component during early diastole (TV-E), tricuspid valve inflow Doppler component during atrial contraction (TV-A), aortic valve peak velocity (AV-max), aortic valve velocity-time integral (AV-VTI), pulmonary valve peak velocity (PV-max), pulmonary valve velocity-time integral (PV-VTI) measured by pulse Doppler, the mitral annular tissue Doppler component during systole (MV-s′), mitral annular tissue Doppler component during early diastole (MV-e′), mitral annular tissue Doppler component during atrial contraction (MV-a′), tricuspid annular tissue Doppler component during systole (TV-s′), tricuspid annular tissue Doppler component during early diastole (TV-e′), tricuspid annular tissue Doppler component during atrial contraction (TV-a′), interventricular septum annular tissue Doppler component during systole (IVS-s′), interventricular septum annular tissue Doppler component during early diastole (IVS-e′), interventricular septum annular tissue Doppler component during atrial contraction (IVS-a′) measured by tissue Doppler, the normal values of left atrial volume (LAV), left ventricular end-systolic volume (LVEDV), stroke volume (SV) and cardiac output (CO) measured by bi-plane method and the normal values of LVEDV, SV and CO measured by real-time tri-plane method, together with the normal values of left ventricular (LV) mass, left ventricular mass index [LV mass/BSA, LV mass/H2.7, body surface area (BSA) and height (H)], all showed nonlinear positive correlations with body weight (all P0.05). Except for RV, MV-D1, MV-D2, MV-D3, TV-D1, TV-E, MV-s′, IVS-a′, TV-s′and TV-e′, all R2 obtained by nonlinear regression method (lnY=a+bX+cX2+dX3) were larger than those obtained by linear regression method (Y=a+bX). The Z score showed a normal distribution and no correlation with body weight. Conclusions The normal reference values of newborn undergoing echocardiography reflect the variation in weight. The Z scores can be obtained by the predicted nonlinear regression equations and show standard normal distribution. The echocardiography normal reference values have important significance for the diagnosis and treatment of neonatal heart disease.

10.
Chinese Journal of Postgraduates of Medicine ; (36): 24-26, 2011.
Article in Chinese | WPRIM | ID: wpr-416020

ABSTRACT

Objective To investigate the influence of brain natrluretic peptide(BNP) in the prognosis of cardiac surgery.Methods Selected 115 cases of pafients with the first cardiac surgery.Their BNP concentration was measured before operation. Observed the relationship between BNP and postoperative atrial fibrillation,mechanical ventilation time,hospital stay,and the mortality of 30 d.Results Whether the patients had hypertension,diabetes,myocardial infarction history,left main stem disease and hemoglobin level or not,showed no definite relationship with BNP (P>0.05).Preoperative lower left ventricular ejection fraction (LVEF)(P=0.002) and European system for cardiac operation risk evaluation [(5±3)scores](P=0.003) were associated with higher BNP level.Postoperative mechanical ventilation time was(15.0±5.4)h,hospital stay was (32±11) d,showed a clear relationship with BNP(P= 0.035,0.001),but postoperative mediastinal infection,atrial fibrillation and mortality of 30 d had no definite relationship with BNP(P>0.05).Conclusion BNP can be used to predict the risk after cardiac surgery.

SELECTION OF CITATIONS
SEARCH DETAIL